Outdoor electrics

Outdoor and garden electrics

Anything outdoors needs a supply designed for being outdoors: correctly rated accessories, RCD protection, and armoured cable at the right depth if it's going underground. It's the burial and the terminations that decide whether it lasts.

What we can help with

If your job isn't on this list, ask anyway. It's a summary rather than a limit.

  • Outside sockets and weatherproof isolators
  • Garden and driveway lighting, including PIR and dusk-to-dawn switching
  • Armoured supplies to sheds, garages, workshops and garden offices
  • Small consumer units in outbuildings, so the building has its own protection
  • Hot tub supplies and their isolation requirements
  • Power for gates, pumps, security cameras and EV chargers on detached buildings

Getting a proper supply to an outbuilding

A garden office, workshop or garage that's going to have lights, sockets and a heater needs its own circuit and its own small board, not an extension lead through a window, and not a spur off the nearest socket.

  • Steel wire armoured cable, sized for the load and the run length so voltage drop stays within limits.
  • Buried at a sensible depth with warning tape above it, and the route recorded so nobody puts a spade through it in two years.
  • A small consumer unit in the building, so a fault out there doesn't take the house out.
  • The earthing arrangement thought about properly, outbuildings on a PME supply sometimes need a separate earth electrode rather than the house's earth.

It's more work than a spur, and it's the difference between something that passes an inspection and something that gets coded on one.

Garden and driveway lighting

Restraint reads as expensive here. Lighting a couple of things well, a path, a tree, the front of the house, looks far better than flooding the whole garden.

  • Warm colour temperature outdoors. Cold white makes a garden look like a car park.
  • Light downwards or across, not up into windows and neighbours' bedrooms.
  • PIR for security lighting, dusk-to-dawn or a timer for the decorative circuits, on separate switching.
  • Fittings with a real IP rating and stainless or marine-grade fixings, particularly anywhere exposed.

Hot tubs and outdoor appliances

A hot tub is a substantial continuous load, often close to what a domestic shower draws, and it needs a dedicated circuit with its own RCD protection and a weatherproof isolator within reach of the tub.

Worth checking the tub's actual requirements before the base goes down: some need a 32A supply, and finding that out after the patio is laid is an expensive discovery.

Why outdoor installations fail

Almost always water, and almost always at a joint. Cheap enclosures with the gland fitted the wrong way up, or a cable entering from the top so water runs straight down inside it.

Cable glanded from below, correct gaskets, accessories rated for their position, and a drip loop where the cable leaves the wall. Small details, but they're why one installation looks fine after ten winters and another is tripping an RCD after one.

FAQs

Outdoor electrics, common questions

Can I run an extension lead to my shed permanently?

No. Extension leads are for temporary use, they're not weatherproof, and they're a common cause of tripping and damaged cable. A shed you actually use wants a proper armoured supply and a small board of its own.

How deep does outdoor cable need to be buried?

Deep enough to be out of reach of normal gardening and any likely future digging, with warning tape laid above it, typically around 450mm under a lawn or border, and deeper under a drive. Depth is judged against what the ground is used for, so we agree the route with you before digging.

Do I need planning permission for a garden office supply?

The electrical supply itself doesn't need planning permission. The building might, depending on its size and position. That's a question for East Staffordshire Borough Council. The electrical work is notifiable and gets certificated either way.

Can you add an outside socket to an existing circuit?

Sometimes, if the circuit has the capacity and suitable protection. It gets tested first rather than assumed. Where the existing circuit isn't suitable, a dedicated one is usually a small job and a much better result.

Related

You might also need

  • Lighting

    Downlights, kitchen and bathroom lighting, switching and dimming that actually works, planned around the room rather than spaced out on a grid.

    Read more
  • EV charger installation

    Home and workplace charge points, installed properly: surveyed, wired, tested and certificated, with the cable run planned so it looks tidy.

    Read more
  • Consumer units & fuse boards

    Replacing old fuse boards with a modern metal-clad consumer unit, properly labelled, properly tested, and sized to leave room for what you add next.

    Read more

Working in Uttoxeter and the surrounding area.

Get a quote for outdoor electrics

Tell us a bit about the property and what you need doing. If photos would help explain it, send those too.

KS Electrical · Uttoxeter, Staffordshire · NAPIT registered

Call KS Electrical on 07508 696028Get a quote